23
Aspirante pumped electric
1 Shower
inoperable, no
water flow when
the start/stop
button is pressed.
2 Water too hot.
3 Water
temperature
cycling hot/cool at
intervals.
4 Water too cool
or cold.
1.1 Interrupted power
supply.
1.2 Plug not connected
to socket inside the cover.
1.3 Solenoid valve
malfunction.
1.4 Pump motor faulty.
2.1 Not enough water
flowing through the
shower.
2.2 Increase in ambient
water temperature.
3.1 Heater cycling on
outlet thermal cut-out.
4.1 Too much flow.
4.2 Reduction in the
ambient water
temperature.
4.3 Electrical malfunction
or safety cut-out has
operated.
1.1.1 Check if a general power cut. Check
other appliances and if necessary, contact the
local Electricity Supply Company.
1.1.2 If the power neon does not illuminate
when the Start/Stop button is pressed, check
the consumer unit fuse or circuit breaker or
isolating switch. If blown or faulty, renew or
reset as applicable. If it fails again, consult a
competent electrician.
1.2.1 Remove the cover and make sure the
plug and socket are firmly connected.
1.3.1 Have solenoid checked by a competent
electrician or contact Customer Service.
1.4.1 If the power neon is lit when the
Start/Stop button is pressed, have the pump
checked by a competent person or contact
Customer Service.
2.1.1 Increase the flow rate via temp. control.
2.1.2 Blocked sprayhead – clean or replace
sprayhead.
2.1.3 Blocked filter – see ‘filter maintenance’.
2.2.1 Switch to reduced power setting and
readjust flow rate (via temperature control) to
give the required temperature.
3.1.1 See 'Water too hot' causes 2.1 and 2.2
and their appropriate action/cures. If it
continues, contact Triton Customer Service.
4.1.1 Reduce the flow rate via the temperature
control.
4.2.1 Switch to full power setting and readjust
the flow rate using the temperature control to
give the required temperature.
4.3.1 Have the shower unit checked by a
competent electrician or contact Customer
Service.
FAULT FINDING
IMPORTANT: Switch OFF the electricity at the mains supply and remove the circuit fuse
before attempting any fault finding inside the unit.
Problem/Symptom Cause Action/cure

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Triton ASPIRANTE Series and is the answer not in the manual?

Triton ASPIRANTE Series Specifications

General IconGeneral
Maximum Static Pressure10 Bar
Water Entry PointsRight Hand Side - Top, Bottom, Back
Cable Entry PointsRight Hand Side - Top, Bottom, Back
TypeElectric
ControlsPush button
FeaturesPush Button Start/Stop

Related product manuals