T70Z electric shower
23
FAULT FINDING
Problem
Cause Action
X-008-A
Blown fuse or circuit breaker. Check
supply. Renew or reset fuse or circuit
breaker. If it fails again, consult a
qualied electrician.
Power cut? Check other appliances and if
necessary, contact local Electricity Supply
Company.
Check if isolating valves are fully open.
Check for a blockage in inlet lter or in
pipework.
Have unit checked. Contact Customer
Experience.
Increase ow rate via temperature
control.
Blocked showerhead clean or replace
blocked sprayplate in showerhead.
Check if stop valves are fully open. Check
if blockage in inlet lter.
Readjust ow rate to give increased ow.
Select economy power.
See 'Water too hot' causes 2.1, 2.2 and
2.3 and their appropriate action/cures. If
it continues, contact Customer
Experience.
Reduce ow rate via temperature control.
Is water supply mains or tank fed?
If tank fed, replumb to mains water
supply or see 4.2.4.
If mains fed, make sure that the mains
stopvalve is fully open and there are no
other restrictions in the supply while
shower is in use, or see 4.2.4.
Fit pump to give minimum pressure (see
rating label). Contact Customer
Experience for advice.
Readjust ow rate to give reduced ow.
Select high power.
Have unit checked by suitably qualied
electrician or contact Customer
Experience.
Wait until the water pressure resumes to
normal.
Clean or replace blocked sprayplate in
showerhead and then t new PRD.
Check for free passage through hose.
Replace the hose if necessary and t new
PRD.
Fit new PRD. Commission unit with
showerhead removed.
Fit pressure reducing valve to inlet and
then t new PRD.
Replace switch
Replace solenoid valve.
Have unit checked. Contact Customer
Experience.
1.1.1
1.1.2
1.2.1
1.3.1
2.1.1
2.1.2
2.2.1
2.3.1
2.3.2
3.1.1
4.1.1
4.2.1
4.2.2
4.2.3
4.2.4
4.3.1
4.3.2
4.4.1
5.1.1
6.1.1
6.2.1
6.3.1
6.4.1
7.1.1
7.2.1
7.3.1
Interrupted
power supply.
No mains water
supply to
shower.
Unit
malfunction.
Not enough
water owing
through the
shower.
Blockage in
supply.
Increase in
ambient water
temperature.
Heater cycling
on outlet
thermal cut-out.
Too much ow.
Water pressure
below minimum
required (see
rating label).
Reduction in
ambient water
temperature.
Electrical
malfunction or
safety cut-out
operated.
Water pressure
has dropped
below minimum
required.
Blocked
showerhead.
Twisted/blocked
exible shower
hose.
Showerhead not
removed while
commissioning.
Water pressure
above specied
maximum for
unit (see rating
label).
Faulty Start/Stop
switch
Debris in
solenoid valve.
Unit
malfunction.
1.1
1.2
1.3
2.1
2.2
2.3
3.1
4.1
4.2
4.3
4.4
5.1
6.1
6.2
6.3
6.4
7.1
7.2
7.3
Shower
inoperable, no
water ow.
Water too hot.
Water temperature
cycling hot/cool at
intervals.
Water too cool or
cold.
Shower varies from
normal
temperature to
cold during use.
Pressure relief
device has
operated (water
ejected from PRD
tube).
Shower fails to
shut off ow when
Start/Stop button
is pressed.
1
2
3
4
5
6
7
Y-001-A
In the unlikely event of unit failure other than detailed in the fault nding page,
please contact Customer Experience for advice.
N-003-A
Note: Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.