10 EN
garden pump TGP 1005 E
4. Open the screw plug at the water drain nozzle(5) to drain
any residual water from the pressure line and from the
inside of the device.
5. Detach the pressure and suction line.
6. Clean the device according to the Maintenance chapter.
7. Store the device according to the Storage chapter.
Available accessories
Accessories Article number
TDP DSP (with plug) 4,610,000,291
TDP DS 4,610,000,290
Errors and faults
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Warning
The device is pressurized. Before opening the screw
plug at the water filler neck(3) or water drain
nozzle(5), the pressure must be released from the
pressure line via the lowest-level consumer.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
• Check the power connection.
• Check the power cable and mains plug for damage.
• Check the on-site fusing.
• The device might have overheated and the overheating
protection has tripped.
In this case, the device will restart automatically as soon
as it has cooled down sufficiently. If the device is not
starting, have the electrics checked by a specialist
company or by Trotec.
• The water temperature is above 35°C and the thermal
protection circuit is activated.
The device is running, but not sucking in any water:
• Check whether the suction line is submerged in the
pumping medium and/or check whether the water level of
the pumping medium is sufficient.
• Check whether the screw plugs at the water filler neck(3)
and water drain nozzle(5) are completely closed and
whether the seal is installed correctly.
• Check the inside of the device for any remaining air. Open
the screw plug at the water filler neck(3) and fill the
device with water all the way to the edge.
• Check the suction line and the connection for tightness.
• Check whether the suction height is too high, and reduce it
if necessary.
• Check whether the hose line is kinked or blocked. Remove
kinks and/ or blockages.
Insufficient or decreasing conveying capacity: