EasyManua.ls Logo

True CS400 - Page 136

True CS400
143 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 7: ADDITIONAL INFORMATION
TRUEfitness.com / 800.426.6570 / 636.272.7100 132
TROUBLESHOOTING GUIDE (continued):
Fault A111:
Motor
Controller Fault
AC MCB Illegal Speed Command
Dirty or misaligned
speed sensor
Contact dealer or TRUE
service
High Belt Deck Friction
Lubricate treadbelt
Contact dealer or TRUE
service
Low Line Voltage
Check AC line voltage
Fault A112:
Motor
Controller Fault
AC MCB Phase over current(RMS)
Loose Cable Connection
Power cycle
Check cable connections
Motor Control Board
Contact dealer or TRUE
service
Fault A113:
Speed Sensor
Fault
AC MCB Faulty Speed Sensor
Dirty or misaligned
speed sensor
Contact dealer or TRUE
service
High Belt Deck Friction
Lubricat treadbelt
Contact dealer or TRUE
service
Low Line Voltage
Check AC line voltage
Fault A114:
Motor Over
Temp
AC MCB Heat Sink Over Temperature
High Belt Deck Friction
Lubricat treadbelt
Contact dealer or TRUE
service
Low Line Voltage
Check AC line voltage
Fault A115:
Motor Over
Temp
AC MCB
Over Temperature on Motor
Drive
High Belt Deck Friction
Lubricat treadbelt
Contact dealer or TRUE
service
Low Line Voltage
Check AC line voltage
Fault A116:
Motor
Controller Fault
AC MCB Brake Gate Driver Fault
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE
service
MCB
Fault A117:
Motor
Controller Fault
AC MCB Phase A low Gate Driver Fault
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE
service
MCB
Fault A118:
Motor
Controller Fault
AC MCB Phase B Low Gate Driver Fault
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE
service
MCB
Fault A119:
Motor
Controller Fault
AC MCB Phase C Low Gate Driver Fault
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE
service
MCB
Fault A120:
Motor
Controller Fault
AC MCB Output Peak Over Current
Loose Cable Connection
Check cable connections
Drive Motor
Contact dealer or TRUE
service
MCB

Table of Contents