REFRIGERATED FOOD PREP
TEC_TM_090 | REV. C | EN 12/13/2022 Page 13 of 24
www.truemfg.com
Cabinet Operation (cont.)
Mechanical Temperature Control
Inside right wall.
Electronic Temperature Control with Digital Display
On the front of the grill.
Electronic Temperature Control with Digital Display
On the front of the grill.
Electronic Temperture Control without Display
Behind the front grill.
Refrigerator and Freezer Cabinets
When the cabinet is plugged in
Interior lights will illuminate on glass door models (see
previous page for light switch location).
An electronic control with digital display will illuminate (if
installed).
There may be a short delay before the compressor and/
or evaporator fan(s) start. This delay may be determined
by time or by temperature, which could be the result of an
initial defrost event that will last at least 6 minutes.
The temperature control/thermostat may cycle the
compressor and evaporator fan(s) on and off together. Every
cabinet will require a defrost event to ensure the evaporator
coil remains clear of frost and ice buildup. Defrost is initiated
by a defrost timer or by the electronic control.
EXCEPTION – Models TSID, TDBD, TCGG, and TMW do
not have an evaporator fan(s).
The temperature control/thermostat senses either an
evaporator coil temperature or air temperature, NOT product
temperature.
An analog thermometer, digital thermometer, or electronic
control display may reflect the refrigeration cycle swings
of up and down temperatures, NOT product temperature.
The most accurate method to determine a cabinet's
operation is to verify the product temperature.
Refrigerators with mechanical temperature controls will
defrost during every compressor off-cycle.
Freezers with mechanical temperature controls will defrost
by time initiation as determined by a defrost timer.
EXCEPTION – Models TFM, TDC, THDC and TMW
require a manual defrost. The frequency of this manual
defrost will depend on the cabinet's usage and ambient
conditions.
An electronic control with a digital display (if installed) will
show def during defrost.
NOTE: The display may have a short delay before
showing a temperature after a defrost event has expired
and instead show def during a refrigeration cycle.
Models with an analog or digital thermometer may show
higher than normal temperatures during defrost.
A refrigerator will use the evaporator fans to clear the coil
during defrost.
EXCEPTION – Models TSID, TDBD, and TCGG do not have
an evaporator fan(s).
A freezer will use heaters to clear the evaporator coil during
defrost.
NOTE: The evaporator coil heater and drain tube heater
are only energized during defrost. Defrost is terminated
when a specific evaporator coil temperature is reached or
by a time duration.
Model(s): TPP, TUC, TWT (Deep Undercounter or
Worktop Models)
ECO
°C
°F
ECO
°C
°F