DuoControl Operation
45EN
50020-00984 ∙ 00 ∙ 08/2022
4 Operation
4.1 Starting up

Open the gas remote switch if present�

Connect the gas cylinder and ensure that the hose connection is
in perfect condition�

Open the cylinder valve�

Firmly press the hose rupture protection on the high-pressure
hose for 5seconds if necessary

Reset the reset button if necessary
The system is now ready for operation� The gas appliances can be
used�
4.2 Resetting the reset button
Fig� 7

To reset the gas pressure regulator, press the black reset button
with the T20Torx pin of the screw aid in the housing and gently
turn in an anti-clockwise direction�

Ensure that the black reset button remains engaged� Repeat the
procedure if necessary