4.3 Changing the gas cylinder
Use the included screw aid to attach and remove the high-pressure
hose� The screw aid helps you generate the necessary tightening
torque and prevents damage to the union that may otherwise result
from using an improper tool�

WARNING
Risk of fire and explosion hazard due to residual gases
Residual gases may escape and form a flammable gas mix-
ture with the air when the cylinder is changed�

Do not use any naked flames or open fire�

Do not smoke�
4.3.1 Gas cylinder with cylinder valve

Close the cylinder valve of the empty gas cylinder

Unscrew the high-pressure hose from the cylinder valve with the
screw aid�

Replace the gas cylinder

Screw the high-pressure hose onto the cylinder valve of the full
gas cylinder with the screw aid�

If a gas filter is present, change the filter pad (see the operating
instructions for the gas filter)�

Open the cylinder valve of the full gas cylinder

If available, press the hose rupture protection on the high-pres-
sure hose�

Set the control knob on the gas pressure regulator to the full gas
cylinder (operating cylinder)� To to this, turn the control knob 180°
to the stop position�

Turning it to the intermediate position causes a simultaneous
withdrawal of gas from both gas cylinders� The intermediate
position should be avoided�

If necessary, press the black reset button on the gas pressure
regulator and gently turn in an anti-clockwise direction�