DuoControl Accessories
53EN
50020-00984 ∙ 00 ∙ 08/2022
The following points must be checked if there are problems with the
gas supply:
Check the fill level of the gas cylinder�
Check that the cylinder valve is opened�
Check the hose rupture protection* if one is in use�
Check whether the switchover system is set/adjusted correctly�
Check whether the reset button was triggered (see chapter „Reset
button“)
Check whether the quick-acting shut-o valves on the gas appli-
ances (heating, oven, gas hob, etc�) are open�
The gas pressure regulator may ice up at temperatures around 0
°C� If the gas pressure regulator ices up, the gas flow is reduced or
completely interrupted� To ensure an uninterrupted gas supply at low
temperatures, Truma also oers the EisEx regulator heater�
8 Accessories
High-pressure hoses
with hose rupture protection and country-specific connections, see
www�truma�com
Flat gasket G.13
for high-pressure connection, M20x1�5 (G�13)
Part number: 50020-76300
Other accessories
(see www�truma�com)