20
Technical data
Determined on the basis of EN 14511 or Truma test conditions
Designation
Saphir comfort RC, comfort air conditioning system
Number of structural units
1
Dimensions L x W x H
628 x 400 x 290 mm
Weight
approx. 23.5 kg
Power supply
230 V – 240 V ~, 50 Hz
Maximum cooling power
2.4 kW
Heating power
1.7 kW
Effective power consumption
0.98 kW
Starting current
20 A (150 ms)
Power consumption
4.2 A
Protection class:
IP X5
Energy Efficiency Rate (EER)
2.4
Volume flow (cold air)
max. 380 m³/h
Refrigerant
R 407C / 0.45 kg
Contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Hermetically sealed.
Global warming potential (GWP)
1774
CO equivalent
798.3 kg
Compressor oil
Diamond MA32, 300 cm³
Noise
depending on installation situation
Maximum incline of vehicle during
operation
5° / 8 %
Usage limits
+4 °C to +43 °C.
An interior air sensor prevents the compressor from operat-
ing at temperatures of less than +16 °C during cooling.
An anti-freeze sensor prevents non-permitted ice formation
on the evaporator coil.
A temperature switch prevents excessive current and tem-
perature at the compressor.
E24 10R-040991
Right reserved to make technical changes!
Circulated air intake
from inside
Cold air /
warm air outlet
Supply air
intake from
the outside
Supply air outlet
to the outside-
downwards
Throttle
Compressor
Fan
Fan
Filter
Function diagram
Evaporator /
condenser
Condenser /
evaporator
Fig. 12
Installation dimensions
The dimensions are in mm.
Ø 50
KO
Saphir comfort RC
LA
HW
HW
LE
620
186
301
400
197.5
74
96
213.5
81
15
122
28
10
Ø 50
KO
488
Fig. 13