EasyManua.ls Logo

Trynex Sweepex SWB-400 - Maintenance Schedule

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22 © TrynEx International 2013 (REV A) F51231A
Maintenance Instructions
Maintenance Plan / Cleaning
before every
use
after the following operating hours
after 3 month
min.
at least
anually
after every
cleaning
5 10 25 50 100
Check screws and nuts
C
Check motor oil level, rell if necessary
C
First motor oil change
S
All further motor oil changes
S S
Check air lter
C
Clean air lter element, earlier if necessary
M M
Replace air lter element, earlier if necessary
M
Replace fuel hoses
S (2 Years)
Clean cool air screen
M
Clean bafe plate, cooling ribs, earlier if neces-
sary
S
Clean spark plugs, adjust gap
S
Replace spark plugs
S
Clean exhaust
M
Lubricate all moving parts
M M
Check hand lever play setting
C
Check brush wear, earlier if necessary
C
Stretch chain drive
C S
KEY
S Maintenance by Specialist
C Check by Operator
M Maintenance by Operator
IMPORTANT
If you are not intending to use the machine for a long time, it should be properly stored. Please contact your local dealer for
suitable storage practices in your geographic location.
CLEANING
To keep your SWB-400 in good condition, you should clean it regularly.
Remove loose dirt or dust with a car wash brush. Wash plastic surfaces with water and soap. Use normal car cleaning soap. Rinse off all
cleaners thoroughly with clean water.
To give plastic parts a gloss nish, use a plastics care product.
Observe the instructions on the cleaning solution package.
You can use glycerine as a corrosion protection for heavily soiled parts.
Do not use pressure washers, the high pressure may force water into bearings, seals and the motor, causing damage.