EasyManua.ls Logo

Tufner T903 - Maintenance; Regular Error and Solution

Tufner T903
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Time: 11:10:41
Time: 11:10:41
Vehicle:
Vehicle:
Cargo:34
Cargo:34
LW:
420.5kg
LFW:
420.5kg
RW:
419.5kg
RFW:
419.5kg
Axle01:
840.0kg
Axle01:
840.0kg
LW:
309.5kg
LRW:
309.5kg
RW:
297.0kg
RRW:
297.0kg
Axle02:
607.0kg
Axle02:
607.0kg
------------------------------
LFW:
420.5kg
Net: 1447.0kg
RFW:
419.5kg
Tare:0.0kg
Axle03:
840.0kg
Gross: 1447.0kg
LRW:
309.5kg
Operater:
RRW:
297.0kg
Axle04:
607.0kg
------------------------------
Net: 2894.0kg
Tare:0.0kg
Gross:
2894.0kg
Operater:
7.Maintenance
7.1 Regular error and solution
ERROR
REASON
SOLUTION
UUUUUU
1.Overload
1. reduce the weight
2.wrong
connection
2. check load cell connection
with load cell
3. inspection load cell. Check
3. load cell has quality
the input and output
problem.
nnnnnnn
1.calibration is no good
1. check scale is resisted or
2. wrong connection
not, foot is kept level or not.
3. load cell has quality
2. check load cell connection.
problem
3. checking load cell
ERR10
Zering, not on stable
Zering, on stable weighing
weighing condition.
condition
ERR11
Zero and tare at same
Back to G.W, then Zero
time.
ERR12
Out of the zero range
Move the extra load
ERR15
Tare, no
on stable
Tare after stable weighing