ISSUE RESOLUTION
F8: Heat Low
Oven Not Warming Up
1. Check that the blower motor is moving air.
o
Blower motor is not moving air: Check blower motor assembly
and verify motor is stalled. Unplug oven and correct obstruction or
replace motor. (For access to motor shaft, remove top panel.)
o
Blower motor is moving air: Verify high-limit thermostat is
not tripped. See the high-limit thermostat information below.
High-Limit Thermostat:
o
Thermostat tripped: Reset and determine why the thermostat
tripped (See Figure 38, Item 114). Look for excess build up of
grease inside the oven or any other source for a fire.
o
Thermostat is not tripped: Check main convection heater.
1.
Convection heater is defective: Unplug oven and replace the
convection heater and verify the K4 SSR (Figure 37) is not
shorted across output.
2.
Convection heater OK: Check the K4 SSR.
o
K4 defective: Unplug oven and replace.
o
K4 OK: Unplug oven and verify all wiring. Verify P1 voltage on
I/O board is 5.0VDC (+/- 0.02) - see Figure 40, page 54.
F2: Cook Temperature
Low
1.
Verify Cook Door Operation.
o
“Cook Door Open” Message: Verify which switch is not actuating
and readjust. See pages 38-43.
o
Cook Door OK: Verify high-limit thermostat is not tripped. See
the high-limit thermostat below.
High-Limit Thermostat:
o
Thermostat tripped: Reset and determine why the thermostat
tripped (See Figure 38, Item 114). Look for excess build up of
grease inside the oven or any other source for a fire.
o
Thermostat is not tripped: Check main convection heater.
1. Convection heater is defective: Unplug oven and replace the
convection heater and verify the K4 SSR (Figure 37) is not
shorted across output.
2. Convection heater OK: Check the K4 SSR.
o
K4 defective: Unplug oven and replace.
o
K4 OK: Unplug oven and verify all wiring. Verify P1 voltage on
I/O board is 5.0VDC (+/- 0.02) - see Figure 40, page 54.
CONVECTION CIRCUIT TROUBLESHOOTING
THE CONVECTION CIRCUIT
49