Do you have a question about the Tyco DV-3 and is the answer not in the manual?
Brand | Tyco |
---|---|
Model | DV-3 |
Category | Control Unit |
Language | English |
Provides an overview of the Model DV-3 Automatic Resetting Deluge Valve and its applications.
Lists UL, C-UL, FM, and LPCB approvals for the DV-3 valve.
Details the valve's ratings, dimensions, materials, and nominal installation dimensions.
Explains the importance and lists components of different trim packages.
Diagram illustrating the wet pilot detection system configuration.
Describes the requirements and operation of the wet pilot detection system.
Lists and illustrates parts for the wet pilot actuation trim assembly.
Provides nominal installation dimensions for the wet pilot actuation trim.
Diagram showing the dry pilot detection system configuration.
Explains the requirements and operation of the dry pilot detection system.
Details the requirements for dry pilot line air pressure based on water supply.
Lists and illustrates parts for the dry pilot actuation trim assembly.
Diagram illustrating the electric detection system configuration.
Describes the requirements and operation of the electric detection system.
Lists and illustrates parts for the electric actuation trim assembly.
Provides nominal installation dimensions for the electric actuation trim.
Illustrates and explains the set and open states of the deluge valve mechanism.
Explains how the deluge valve operates based on water pressure and actuation.
Clarifies that the actuation device must remain open for the valve to stay open.
Provides general notes and recommendations for valve installation.
Details the step-by-step procedure for installing the DV-3 Deluge Valve.
Recommends using internally galvanized pipe and cast iron fittings for pilot lines.
Outlines the steps for initially setting the Model DV-3 Deluge Valve.
Details procedures for resetting manual, wet pilot, dry pilot, and electric actuation.
Advises replacing pilot sprinklers exposed to high temperatures.
Outlines required inspections and maintenance for the fire protection system.
Describes actions to take if water supply pressure drops significantly.
Details the annual procedure to verify the DV-3 Valve's operation.
Specifies the procedure for internal inspection of the valve every five years.
Specifies how to order DV-3 valves with ANSI or ISO pipe connections.
Details ordering procedures for trim packages, replacement parts, and accessories.
Provides nominal weights for the valves and trim assemblies.