SELF-INSPECTION OF THE INSTALLATION
To check the installation:
1. Switch on the mains supply to the heater from the distribution
board.
2. Check that the control panel lights up.
3. Start the heater (see User Guide).
4. Check that all three tubular elements start to heat up (go
red).
Please keep these instructions!.
In the event of problems, please contact the retailer where you purchased
the equipment.
© This publication many not be reproduced, in part or in whole, without
the written permission of Tylö. Tylö reserves the right to make changes to
materials, construction and design.
Description of cabling/modular contacts
NOTE! Crimp pliers are needed if changing modular
cabling, e.g. shortening wires.
1234Pin:
1234Pin:
1
2
3
4
12
6789
34 5
Cable
Solid conductor
Cable
Stranded conductor
Max. Ø3,6mm
OK!
Fig 20. Modular plug/modular contactor, relay board "high" and multithreaded lead
1. Modular plug RJ10, used with cable (max. cable cross-section for connection of modular plug: 0.14-0.20 mm² / AWG26-AWG24)
2. Modular jack RJ10, connected to relay board and control panel
3. Relay board "high" (Pos. 6-9 white connectors)
4. Cable/lead connected to the modular plug must be multithreaded
Table 3: Description of relay board connections
Pos Unit Use pin Comment Pin1 Pin 2 Pin 3 Pin 4
1 - NTC Temp. sensor in the room 2, 3
10kΩ. May also be con-
nected at Pos 4 - SEC/
NTC.
Not use 10kΩ 10kΩ Not use
2 - EXT
SWITCH
External switch 3, 4
Start/stop operation.
Constant or impulse
deactivation.
Not use Not use Switch Switch
External switch with LED indica-
tion
2, 3, 4
Start/stop operation.
12VDC max. 40mA.
Tylö Item no.: 90908048
Not use Led GND Switch
Switch /
Led 12V
3 - DOOR
SWITCH
Door contact (NO) 3, 4 Tylö Item no.: 90908035 Not use Not use Switch Switch
Door contact (NO) with an exter-
nal alarm indication
2, 3, 4
12VDC max. 40mA.
External junction box, not
for sale.
Not use Led GND Switch
Switch /
Led 12V
4 - SEC/NTC
Combined tempe-
rature sensor/cut-
out in the room
Temp. sensor
10kΩ
2, 3
Only used for certain
products.
Sec 10kΩ 10kΩ Sec
Temperatu-
re cut-out
130°C
1, 4
Adapter for activation of opera-
ting status
1, 4 Steam Commercial Sec Not use Not use Sec
5 - ADD-ON Extra relay board
1, 2, 3, 4,
5, 6, 7, 8
Note: Not for network
connection.
6-9 - RS485
Control panels 1, 2, 3, 4
Tylö Elite and Pure con-
trol panels.
A (RS485) B (RS485) 12V GND
Temp./Humidity sensor % 1, 2, 3, 4
Combi heater with Elite
control panel and Tyla-
rium.
A (RS485) B (RS485) 12V GND
Synchronisation cable A/B 1, 2
Multisteam and Tylarium.
Primary and secondary
units.
A (RS485) B (RS485) Not use Not use

Other manuals for Tylo SENSE ELITE

Related product manuals