EasyManua.ls Logo

Tylo SENSE ELITE - Connection;Wiring Diagram

Tylo SENSE ELITE
66 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Figure 17: Wiring diagram
1. Heater
2. Sensor - (connect to NTC position 1)
3. Control panel (connect to positions 6-9)
4. External switch (option)
5. Door contact
6. Light/terminal for connection of light / IR
7. Terminal for connection of electrical cable
1
654
3
2
7
RJ10 4P4C
3 x 0.75 mm
2
RJ10 4P4C
RJ10 4P4C
RJ10 4P4C
Control panel Elite - max 30m
*
*
6,6-8,0 kW
200-240 V 1N~/2~
6,6-8,0-10,5 kW
200-230 V 3~
6,6-8,0-10,5 kW
400-415 V 3N~
6
BGGIIB
Max 100W
200-240 V~
INFRA
Max 2,2kW
200-240 V~
CONNECTION/WIRING DIAGRAM
TAB 400-415 V 3N~ (C) 200-208 V 3~ (B) 230 V 3~ (B) 200-208 V~ (A) * 230-240 V~ (A) *
Output
kW
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
6,6 10 1,5 19 4 17 4 33 10 29 10
8 12 2,5 23 6 20 4 40 16 35 10
10,5 16 2,5 32 10 28 10 - - - -
* 10,5 kW is not approved for singel phase in Europe

Other manuals for Tylo SENSE ELITE

Related product manuals