16
Figure 17: Wiring diagram
1. Heater
2. Sensor - (connect to NTC position 1)
3. Control panel (connect to positions 6-9)
4. External switch (option)
5. Door contact
6. Light/terminal for connection of light / IR
7. Terminal for connection of electrical cable
1
654
3
2
7
RJ10 4P4C
3 x 0.75 mm
2
RJ10 4P4C
RJ10 4P4C
RJ10 4P4C
Control panel Elite - max 30m
*
*
6,6-8,0 kW
200-240 V 1N~/2~
6,6-8,0-10,5 kW
200-230 V 3~
6,6-8,0-10,5 kW
400-415 V 3N~
6
BGGIIB
Max 100W
200-240 V~
INFRA
Max 2,2kW
200-240 V~
CONNECTION/WIRING DIAGRAM
TAB 400-415 V 3N~ (C) 200-208 V 3~ (B) 230 V 3~ (B) 200-208 V~ (A) * 230-240 V~ (A) *
Output
kW
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
Amperage
amp
Conductor
area mm²
6,6 10 1,5 19 4 17 4 33 10 29 10
8 12 2,5 23 6 20 4 40 16 35 10
10,5 16 2,5 32 10 28 10 - - - -
* 10,5 kW is not approved for singel phase in Europe