Cleaning
Cleaning time – After a specified number of hours a message will appear with a reminder to clean the tank. This is where
you set the number of hours between cleaning. Use the number of hours indicated by EASY TEST. If no
reminder is needed, set 0 hours.
Last cleaned – Indicates the time that has elapsed since the equipment was last cleaned. ”---” means that the equipment
has not been cleaned.
Tank emptying – Number of hours between automatic tank emptying when the steam bath is operational. Default value is
4 hours.
Diagnostics
Relay control – Only for Tylö service technicians.
Extra relay control – Only for Tylö service technicians.
System status – Shows current status for water level, water temperature, steam bath temperature, electrode value for
level indicator, running time, software/hardware version and product ID.
Heater-net node list – Shows which products are connected to the system.
Error log – Any system errors are logged here.
Factory reset
Enter code 421 to reset the control panel to the factory default settings.
5.6 Error messages
“Sauna temperature sensor
failure.”
in the sauna is either not
connected or has
bathing cycle and is
not able to start a new
connections. Test with
another sensor.
“Tank temperature sensor failure.”
in the sauna is either not
connected or has
bathing cycle and is
not able to start a new
connections. Test with
another sensor.
overheated”.
PCB is greater than
70˚C.
bathing cycle and is
not able to start a new
bathing cycle until the
water temperature is
equal to or below
temperature is equal
to or below 70˚C.
“Fatal error! Unplug power, and
contact service”.
The outputs to the relays
do not match the inputs
from the contactors.
Might be welded relays.
bathing cycle and is
not able to start a new
bathing cycle.
connections. Check
input voltage. Restart
system by toggling the
voltage. If the same
error is repeated,
“Electrode failure! Contact
service.”
three times.
cycle.
electrodes. Check the
“Lost contact with control panel.”
restarted because the
RCB was not able to
communicate with one of
60 seconds when it
has lost the
connection to the
Check the cables and
connections. Change
the control panel.
temperature/humidity sensor.”
restarted because the
RCB was not able to
communicate with one of
60 seconds when it
has lost the
connection to the
the cables and
connections. Change
sensor.
is greater than the limit
cycle.
Check the pipes out
“Hardware error. Contact service”
The real time clock is out
of order.
not being updated.
the same thing
happens again,
“Power outage. Set time.”
Real time clock has been
reset.
Time and date are set
to default.
“Lost contact with fragrance
pump.”
restarted because the
RCB was not able to
communicate with one of
restart after 60
seconds.
Check the cables and
connections. Change
fragrance pump.
19