DISPOSAL OF EQUIPMENT
The instructions for disposal are indicated on the equipment pictograms or their packaging.
For the description of individual meanings, see the chapter "Identification of the equipment".
OPERATOR REQUIREMENTS
Before using the equipment, operator must read the Instructions for use.
QUALIFICATION
In addition to the detailed Introductions of an expert, no special qualification is needed for using of the equipment.
MINIMUM AGE
The equipment can only be handled by people of legal age.
An exception is the use by adolescents, as part of a professional training, to reach proficiency under the supervision of
an Instructor.
The user must have a criterion formed and according to the responsibility that implies the use of a device of these
characteristics.
TRAINING
To use the equipment they only require the corresponding instructions. No special training is required.
LIMIT OF OPERATING ENVIRONMENT,
TRANSPORTATION, AND STORAGE
ATTENTION!:
The equipment must only be used in the working position (on a flat and level surface) because otherwise, there may be
fuel or oil leaks or the lubrication is no longer guaranteed.
If a battery is used, it should be removed when it is not used for a long time and kept in a dry and safe place (for example
in the boiler room).
ASSEMBLY AND STARTING
ATTENTION!
Start up the generator for about 10 minutes every three months.
MINIMUM LEVEL
MAXIMUM LEVEL
( A ) ( B )
WORKING TEMPERATURE
-30 -20 -10 0 10 20 30 40 (C)
0 20 40 60 80 100 (F)
20 W 40
S A E
10 W
20 W
20
30
40
10 W 30
RECOMMENDED VALUE
LIMIT OF USE
A.P.I. CLASSIFICATION OF MAINTENANCE FOR THE DIESEL ENGINE.
WE RECOMMEND SAE15 W 40 API CF DIESEL OIL.
ATTENTION !: IMPORTANT NOTE FOR OPERATION
Always make sure that the generator has enough fuel and engine oil before each start-up. When the fuel system is
completely empty it may be necessary to remove the fuel line to prime it, which must be done by qualified personnel.
AVOID OPERATION WITH EMPTY FUEL TANK!
BEFORE THE OPERATION
• Check the fuel level and recharge it if necessary.
• This generator has a fuel tank with a maximum capacity of 13.5 liters.
• Make sure the fuel is diesel, DO NOT overfill the fuel tank.
• Insert the engine oil through the lubricant inlet with a minimum and maximum capacity (see diagram A).
• Use oil for diesel engine SAE15 W 40 API CF, as recommended in the table of working temperatures (diagram B).
• Turn off the general protector.
• Inspect the area around the generator.
• Disconnect any electrical equipment that is already connected to the generator.
55 56