EasyManua.ls Logo

Ublox SARA-G340 ATEX - Serial Interfaces

Ublox SARA-G340 ATEX
217 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SARA-G3 and SARA-U2 series - System Integration Manual
UBX-13000995 - R26 System description
Page 45 of 217
1.9 Serial interfaces
SARA-G3 and SARA-U2 series modules provide the following serial communication interfaces:
UART interface: 9-wire unbalanced 1.8 V asynchronous serial interface supporting (see 1.9.1)
o AT command mode
17
o Data mode and Online command mode
17
o MUX functionality, including dedicated GNSS tunneling
18
and SIM Access Profile
19
virtual channels
o FW upgrades by means of the FOAT feature
o FW upgrades by means of the u-blox EasyFlash tool
20
o Trace log capture (diagnostic purposes)
20
Auxiliary UART interface
21
: 3-wire unbalanced 1.8 V asynchronous serial interface supporting (see 1.9.2)
o AT command mode
22
o GNSS tunneling
23
o FW upgrades by means of the u-blox EasyFlash tool
24
o Trace log capture (diagnostic purposes)
USB interface
25
: High-Speed USB 2.0 compliant interface supporting (see 1.9.3)
o AT command mode
o Data mode and Online command mode
17
o GNSS tunneling and SIM Access Profile virtual channels
o Ethernet-over-USB
26
virtual channel
o FW upgrades by means of the FOAT feature
o FW upgrades by means of the u-blox EasyFlash tool
o Trace log capture (diagnostic purposes)
DDC interface
27
: I
2
C-bus compatible 1.8 V interface supporting (see 1.9.4)
o Communication with u-blox GNSS positioning chips / modules
o Communication with other external I
2
C devices as an audio codec
28
17
See the u-blox AT Commands Manual [3] for the definition of the command mode, data mode, and online command mode.
18
SARA-G300 and SARA-G310 modules do not support GNSS tunneling.
19
SARA-G3 modules do not support a SIM Access Profile.
20
SARA-G3 modules do not support FW upgrades using the u-blox EasyFlash tool and trace log capture over the UART.
21
SARA-U2 modules product versions “00”, “03”, “53”, “63”, “73” do not provide Auxiliary UART.
22
SARA-G3 modules product versions “00” and “01” do not support AT command mode over the Auxiliary UART.
23
SARA-G3 modules product versions “00” and “01”, and SARA-U2 modules do not support GNSS tunneling over the Auxiliary UART.
24
SARA-U2 modules do not support FW upgrades using the u-blox EasyFlash tool over the Auxiliary UART.
25
SARA-G3 modules do not provide a USB interface.
26
SARA-U2 modules product versions “00”do not support Ethernet-over-USB.
27
SARA-G300 and SARA-G310 modules do not support a DDC I
2
C-bus compatible interface.
28
SARA-G3 modules do not support communication with external I
2
C devices other than u-blox GNSS positioning chips / modules.

Table of Contents