C1-Public
The entire temperature range is divided into sub-regions by limits (see Figure 20) named t
-2
, t
-1
, t
+1
and
t
+2
.
Within the first limit, (t
-1
< Ti < t
+1
), the cellular module is in the normal working range, the safe area.
In the warning area, (t
-2
< Ti < t
-1
) or (t
+1
< Ti < t
+2
), the cellular module is still inside the valid
temperature range, but the measured temperature is approaching the limit (upper or lower). The
module sends a warning to the user (through the active AT communication interface), who can
take, if possible, the necessary actions to return to a safer temperature range or simply ignore the
indication. The module is still in a valid and good working condition.
Outside the valid temperature range, (Ti < t
-2
) or (Ti > t
+2
), the device is working outside the
specified range and represents a dangerous working condition. This condition is indicated and the
device shuts down to avoid damage.
The shutdown is suspended for security reasons whenever an emergency call is in progress. In this
case, the device switches off at call termination.
The user can decide at any time to enable/disable the Smart Temperature Supervisor feature. If
the feature is disabled, then there is no embedded protection against disallowed temperature
conditions.