Reassembly
18. Secure with the clamp clip
Place the blue clamp clip around the tube coupling collet to secure
the Bowden tube.
19. Divide the clips
Evenly divide the clips over the Bowden tube and braided sleeve.
Make sure to keep the braided sleeve on the left of the Bowden
tube.
Tip: Check if the print head is moving smoothly in both directions. If
not, the print head shafts may not be in a 90º angle anymore. In this
case it is recommended to calibrate the print head using the print
head alignment tools.