Model UT105: OPERATING MANUAL
49
General Specifications
l Maximum Voltage between any Terminals and
grounding: Refer to different range input protection
voltage.
l
Fuse Protection of
mA terminal : CE Version: 315mA, 250V,
fast type, 5x20mm
l
Fuse Protection of
10A terminal : CE Version: 10A, 250V, fast
type, 5x20mm
l Measurement Speed : Updates 2-3 times /second.
l Maximum Display : 1999.
l Temperature : Operating: 0
o
C~40
o
C(32
o
F~104
o
F)
Storage: -10
o
C~50
o
C(14
o
F~122
o
F)
l Relative Humidity : 75% @ 0
o
C to below 30
o
C;
50% @ 30
o
C to 40
o
C.
l Altitude: Operating : 2000m; Storage: 10000m.
l Battery Type : One piece of 9V (NEDA1604
or 6F22 or 006P).
l Electromagnetic
Compatibility : In a radio field of 1 V/m,
Overall Accuracy = Specified
Accuracy + 5% of Range;
in a radio field of more than
1 V/m, no assigned accuracy
is specified
l Battery Deficiency : Display .
l Negative reading : Display .
l Overloading : Display 1.
l Equipped with full icons display.
l Manual ranging.
l Polarity: Automatically display.
l Dimensions (HxWxL) : 179 x 88 x 39mm.
l Weight : 380g. (including holster and
battery)
l Safety/Compliances : IEC61010: CAT. II 1000V,
CAT. III 600V overvoltage
and double insulation standard.
l Certification :