44
Model UT805: OPERATING MANUAL
D. AC Current (Frequency range: 40Hz~5kHz)
Remarks:
Overload Protection:
At mA Range:Fuse 315mA, 250V, fast type, 5x20mm.
At A Range :Fuse 10A, 250V, fast type, 5x20mm.
At 5A range: Continuous measurement is allowed.
At >5A range: For continuous measurement 10 seconds and interval not less than 15 minutes.
Displays : The effective reading is only applicable to the range of 10%~100%.
AC+DC Tolerance Limit: Same as AC + 1%.
l
l
l
l
l
Range Measurement Scope Resolution Accuracy
2mA
20mA
10A
0.01 A~2.20000mA
1 A~220.000mA
0.1mA~10.0000A
0.01 A
1 A
0.1mA
(0.3%+100)
(2%+200)