OPERATIONS MANUAL Rev. 1.4
Maintenance Plan
In order achieve a long and trouble-free service life the machine requires a minimum amount of care
and maintenance.
Maintenance works must be carried out only with stopped motor, disconnected power supply and
pressure-free hoses. Danger of injury!
Daily inspection Testing
For the safety of the machine and operator please check following points:
Oil level at the pump.
Visual inspection of the machine and its equipment/accessories (hoses, handle,
lance, fittings, electrical components, other equipment).
Inspection for proper air ventilation from the back of the motor.
High pressure pump.
Pressure gauges.
High pressure hoses.
High pressure handle.
Electric cable.
Function of Emergency stop button.
Water filter, check and replace if contaminated or differential pressure exceeds
1bar.
Check for leakages.
Weekly inspection Testing
First oil change of high-pressure pump after 50 working hours (hour meter is
installed inside the electrical cabinet) and then every 500 working hours.
Checking of oil level of high-pressure pump.
Checking of oil quality.
Replacing of water filter.
Inspecting and cleaning of water tank mesh filter.
After 30 operating hours, check electrical board screws and tight in case of loose
screws.
6-Month inspection
Inspect pump oil appearance and change oil after every 500 hours, after the first
change.
Check electrical board screws and tight in case of loose screws.
Water tank to be drained and cleaned from inside.