23
OPERATIONS MANUAL Rev. 1.4
12-Month inspection
Pump oil seals and valves should be replaced at least once a year as a part of
preventive maintenance for efficient machine performance.
Replacement of Water Filter
Unscrew the plastic transparent cover of the filter housing with the included
tool/spanner.
Remove the old dirty filter and insert the new original 7” cartridge filter.
Screw back filters housing with the supplied filter tool/spanner.
Time interval for replacing the filter depends on supplied water quality. In case of poor water quality
and existence of particles and soil, the filter change should be done frequently may be even daily.
Disposal of the oil of the pump crankcase and disposal of parts and components
of the machine should be done according to regulations.