OPERATIONS MANUAL Rev. 1.4
Water quality requirements
The environment temperature when the high-pressure cleaner operates should be min +4°C
and max + 40°C.
Notes on the requirements for the water used.
The STANDARD pumps work with clean, soft water, at a maximum temperature of 40˚C, and only for
short periods, up to 60˚C.
Temperature
Max. 40° C inflow temperature.
pH
The pH value must be between 6.5 and 9.5.
Conductivity
Conductivity at 20°C must be below 2000 μS/cm.
Purity
The water must be free of abrasive and particulate materials.
NOTE:
It is the responsibility of the operator to ensure that the water quality is per requirements. Prolonged
usage of the machine with poor water quality will lead to severe damages of the machine.