Page 25
Print Mode (C18 = 2)
For printing on a non-adhesive ticket printer. Parameters 16, 17, 30, & 42-45 all eect your
ticket print out.
Normal weighing ticket printout example:
Date: 05/01/2017
Time: 11:30:52
Net: 25.6Ib
Tare: 10.3Ib
Gross: 35.9Ib
Accumulation weighing ticket printout example:
Date: 05/01/2017
Time: 11:30:52
n001 15.4lb
n002 17.2lb
n003 35.6lb
Total 68.2lb
Command Request Mode (C18=3)
In this mode, the indicator can receive ASCII commands as listed below
Command Name Function
1 Tare Save and clear tare
2 Zero Zero gross weight
3 Print Print the weight
4 G.W/N.W
Read gross weight or net
weight
5 Kg/lb Kg/lb conversion
6 G.W
Check gross weight at net
weight mode
The R command will trigger the indicator to output the following data format:
<STX> <POL> XXXXX.XX <SP> <LB/KG> <SP> <GR/NT> <CR> <LF>
Polarity:
<SP>=Positive
“-” = Negative
Weight
Data
Units:
lb = punt
kg = kilogram
pcs = pieces*
Gross/Net: GR
= Gross
NT= Net
Line Feed
Start
Transmission
Space Space Carriage
Return