9
OPERATINGINSTRUCTIONS‐continued
When the pellets have ignited andflame has been established, the start‐upcycle will end; this procedure takes
between8and12minutes.IfthecontrolissettoManualMode,itwillnowdefaulttotheheatlevelsettingthe
lastshutdowntime.Ifthecontrolisset
toT‐STATModetheheatoutputwillcoincidetothecom mandsfromthe
thermostat.
Auger:
As explained in the starting up step, this button is only served to start up the pellet stove in lieu of the on/off
buttonwhentherearenopelletsintheauger.
CirculationAirFlow:
YourPelletStoveRoomHeaterfeaturescirculationairflowwhichwillchangeinaccordancewiththeheatsetting.
Circulationairflowwillbeatitsmaximumsettingwhentheheatsettingisalsoatmaximumandsubsequentlywill
beatitsminimumsettingwhentheheatsettingisatminimum.If
youdesiretooperatethecirculationfanatits
maximumsettingregardlessofheatsetting,youmaydosobypressingtheFANbutton.
AugerTrim:
Whenoperat ing atHeatLevel1, iftheflame goesoutortheheatoutputistoohigh onthe minimumheatlevel
setting,usetheAUGERTRIMbuttontomakeadjustments.SeetheAUGERTRIMbuttondescriptiononpage11.
ShuttingDownYourPelletStoveRoomHeater:
Turn off the heater by pressing the On/Off button. The stove will enter the shutdown cycle and the pellets will
stop feeding into the burn pot to allow the fuel in the burn pot to be combusted and consumed. During this
period,theexhaustblowerandcirculationfanwillcontinueto
operateuntiltheflamesareoutandtheheaterhas
cooleddown.Whentheheaterhascooleddowntoitspre‐setlevel,itwillshutdowncompletely.
CAUTION: NEVER TURN OFF THE HEATER BY UNPLUGGING OR DISCONNECTING ITS ELECTRICAL POWER
SOURCE. DOING SO WILL CAUSETHE HEATER TO SKIPTHE PROPER SHUTDOWN CYCLE,CAUSING THE HEATER
TOOVERHEATANDTHEPOSSIBLERELEASEOFSMOKEINTOTHEHOUSE.