2NM/2NX/2NY/2NZ/2P0/2P6-1
1-3-57
Codes Description Corrective Action
1e Lab value searching error Check the following and perform
again.
- Isn't the bar code dirty?
- Is the position of a original right?
- Is a bar code position right?
1f Lab value comparing error Check the following and perform
again.
- Is the acquired bar code the same?
- Is the position of a original right?
- Is a bar code position right?
20 Input gamma correction coefficient error Set the original correctly and per-
form again.
21 Color correction matrix coefficient error
30 Chromatic aberration adjustment original
error
63 Completed to obtain a test RAW -
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.