Chapter 2: Reporting codes
12 NX-8E Control Panel Installation Manual
LED
Keypad feature enabled
8
Enable multiple partition viewing. Enable temporary viewing of all
partitions by pressing *, 1, partition number.
Keypad number and partition
To set the keypad number and partition:
1. Enter *, 9, 4, program code. The Service LED and the Instant LED will flash.
2. Enter the keypad number (1 to 8).
3. Press *. The Instant LED will illuminate steady and the Service LED will
remain flashing.
4. Enter the partition number (1 to 8) for the keypad. The keypad will
automatically exit this mode at this time.
Elapsed increments
To set the elapsed increments since the last autotest:
1. Enter *, 9, 5, program code. The Service LED begins flashing.
2. Enter the three-digit increment number.
[100;s digit] - [10’s digit] - [1’s digit] - #
System date
To set the system date:
1. Enter *, 9, 6, master code. The Service LED begins flashing.
2. Enter the day for the week, the month, the day of the month, and the year.
Day of the week (one digit) 1 = Sunday, 2 = Monday etc.
Month (two digits) 01 = January, 02 = February, etc.
Day of the month (two digits), 01 to 31.
Year (last two digits of the year).
For example, Sunday, May 7, 2010 = 1, 0, 5, 0, 7, 1, 0.