Appendix A: Reporting codes
68 NX-8E Control Panel Installation Manual
Reporting zone codes in Contact ID and SIA
The NX-8E has the ability to report SIA transmissions to either or both phone
numbers. Each report in SIA consists of an event code and a zone ID (the
number of the zone that is in alarm) or user ID. table shows the event code, SIA
code, and a description that is programmed in the zone type event code
(Locations 110 to 169).
Table 14: Reporting zone codes
Event code
SIA code
Description
0
HA
Holdup alarm
1
FA
Fire alarm
2
PA
Panic alarm
3
BA
Burglary alarm
4
BA
Burglary alarm
5
BA
Burglary alarm
6
UA
Untyped alarm
7
BA
Burglary alarm
8
BA
Burglary alarm
9
UA
Untyped alarm
10
HA
Holdup alarm
11
MA
Medical alarm
12
PA
Panic alarm
13
TA
Tamper alarm
14
RP
Periodic test
15
GA
Gas alarm
16
KA
Heat alarm
17
WA
Water alarm
18
QA
Emergency alarm
19
SA
Sprinkler alarm
20
ZA
Freeze alarm
21
KH
High temperature alarm
22
FA
Manual fire alarm