Chapter 2: Reporting codes
18 NX-8E Control Panel Installation Manual
Programming locations
This section describes all the programming options for the control panel.
Quick start programming
For most routine installations, the quick start locations allow you to enable a
majority of the options available with the NX-8E (when communicating in Contact
ID or SIA formats). The quick start locations include:
Location 0 - Phone 1
Location 1 - Phone 1 account code
Location 2 - Phone 1 communicator format
Location 3 - Phone 1 dial attempts/backup control
Location 6 - Phone 2
Location 7 - Phone 2 account code
Location 8 - Phone 2 communicator format
Location 19 - Download access code
Location 20 - Number of rings to answer
Location 21 - Download control
Location 22 - Download call back number
Location 23 - Feature report selection/partition feature selection
Location 24 - Entry/exit times
Location 25 - Zone type selection for zones 1 to 8
Location 37 - System reporting, operation, and siren options
Location 38 - Swinger shutdown count
Location 39 - Keypad sounder control
Location 40 - System timers
Location 42 - Go to program code
Location 44 - Duress code
Location 51 - Autotest control
Locations 0 to 18 - Reporting
Location 0 - Phone 1
Location 0 has 20 segments of numerical data. Use this location to program
phone 1. The default for each segment is 14.
To program a delay of 4 seconds, enter 13 in the appropriate segment.
To program tone dialing, enter 15 in the segment where tone dialing begins.
If the entire number is tone dialing, enter 15 in the first segment.
Enter 11 for a *, and 12 for a #.