4. Test the operation of the pump by pouring water
into the sump basin.
IL2045
4
CARE AND MAINTENANCE
WARNING: Always disconnect pump from power
source before handling.
At least every three months:
Remove any debris that may build up in the
sump basin to prevent it from interfering with the
operation of the float switch.
Test system for operation.
IL2046
Remove
debris
1
5. If the lower rod stop is positioned 8 in. from
the top of the rod, the pump will turn on
at approximately 10 in. to 12 in. and o󰀨 at
approximately 2-1/2 in. To cycle the pump on
and o󰀨 faster, move the lower oat stop closer
to the oat rod guide.
Float Rod Guide
Lower Float Rod Stop
Top Float Rod Stop