2. SPECIFICATIONS
2.1 GENERAL SPECIFICATIONS
Model No. Capacity Division
OAC-1.2 1200g 0.1g
OAC-2.4 2400g 0.2g
OAC-6 6000g 0.5g
OAC-12 12kg 1g
OAC-24 24kg 2g
OEC-1.2 1200g 0.2g
OEC-3 3000g 0.5g
OEC-6 6000g 1g
OEC-12 12kg 2g
OEC-30 30kg 5g
OVC-1.2 1200g 0.1g
OVC-2.4 2400g 0.2g
OVC-6 6000g 0.5g
OVC-12 12kg 1g
OVC-24 24kg 2g
Tare Range FULL RANGE (SUBTRACTIVE)
Zero Range Maximum = 2% of Rated Capacity
Auto Pieces Weight Enhancement Range:
Min. = 4 pieces
Max. = Max. count previously achieved
Operation
Environment
0
o
~40
o
C (32
o
~104
o
F),
Non-condensed. R.H.¡85%
Power source OAC & OEC: By Built-
in
Rechargeable Battery or Power
Adaptor (or Power Cord)
OVC: By Built-
in Power Pack or
Power Adaptor
Specifications subject to change without notice
2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE
SIZE SPECIFICATIONS
Recommended Minimum Model No.
Piece
Weight
Weight
Applied
Sample
Size
OAC-1.2 0.1g 2g 400g
OAC-2.4 0.2g 4g 800g
OAC-6 0.5g 10g 2000g
OAC-12 1g 20g 4kg
OAC-24 2g 40g 8kg
OEC-1.2 0.2g 4g 400g
OEC-3 0.5g 10g 1000g
OEC-6 1g 20g 2000g
OEC-12 2g 40g 4kg
OEC-30 5g 100g 10kg
OVC-1.2 0.1g 2g 400g
OVC-2.4 0.2g 4g 800g
OVC-6 0.5g 10g 2000g
OVC-12 1g 20g 4kg
OVC-24 2g 40g 8kg