35
10. Installation of the new acrylic sheet bed is performed in the
reverse order.
11. After completely installing the acrylic sheet bed, pull off the
protective foil from the top
of the bed.
Replacing the air separation sheet
1. Unlock the two acrylic locks (6-1/2+3) with the Allen key.
2. Move the acrylic sheet bed (6-1/1) upward. The acrylic sheet
bed is held in open
position by the two gas springs.
3. Unfasten the two mounts (6-3/3) on the air separation sheet
(6-3/2).
4. Remove the air separation sheet (6-3/2) from the bed housing.
5. Remove the air separation sheet.
6. Place the new air separation sheet in the bed housing.
7. Installation of the new acrylic sheet bed is performed in the
reverse order.
Replacing the HP-module acrylic sheet
1. Loosen the screws and remove the acrylic sheet.
2. Secure the new acrylic sheet with the screws
9.3 Facial tanners
In front of each of the three high pressure lamps in the canopy there is an XTT filter disc.
The high pressure lamps may only be operated with the
particular filter configuration specific to the equipment. If filter
discs are damaged or missing, the unit may not be used under
any circumstances. Danger of burning! Danger of permanent
damage to the eyes! Depending on the model, the face tanner may not switch on
immediately if restarted, or will only switch on with reduced
power, as a cooling period of about 4 minutes is required
.To replace a high pressure lamp, please contact the
manufacturer or an authorized dealer. No liability will be
accepted if tubes other than those originally supplied are
used.
BREAKSAFE unit XTT
Each XTT filter disc above the high pressure lamp in the
canopy is equipped with a BREAKSAFE device. If one of
these filter discs breaks, the power supply is cut off and the
unit can only be restarted after the XTT filter disc has been
replaced.