Safe Stop 1 (SS1)
The SS1 safety function is realized in compliance with type C of the drives safety standard EN 61800-
5-2 (Type C: "The PDS(SR) initiates the motor deceleration and initiates the STO function after an
application specific time delay").
The SS1 safety function has been designed for use in accordance with the following standards:
EN 61800-5-2 Safe Stop 1 (SS1) SIL2
EN ISO 13849-1 PL"d" Category 3
EN 62061: SILCL2
IEC 61508: SIL2
The function also corresponds to a controlled stop in accordance with the stop cat. 1, EN 60204-1.
Motor Thermistor Over temperature protection (according to ATEX)
Overtemperature detection using thermistor. It can be used as a tripping device for ATEX certified
motors.
The thermistor tripping function is certified by VTT** according to ATEX directive 94/9/EC.
All safety functions of the OPTBJ board are described in this manual.
** VTT = Technical Research Centre of Finland