EasyManua.ls Logo

Vacon 100 - CIP COMMON REQUIRED OBJECTS

Vacon 100
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
vacon • 18 STO and SS1 safety functions
Tel. +358 (0) 201 2121 • Fax +358 (0)201 212 205
5.2 Safe Stop 1 (SS1) Principle
After a safe stop command the motor starts decelerating and SS1 safety function initiates the STO
after a user set time delay.
Figure 6. The principle of Safe Stop 1 (EN 61800-5-2, SS1 type c)
The Safe Stop 1 (SS1) safety function consists of two safety related subsystems, an external time
delayed safety relay and the STO safety function. These two subsystems combined compose the
Safe Stop 1 safety function as shown in Figure 7.
Figure 7. Safe Stop 1 (SS1) safety function
Time
0
Stop
Motor
deceleration
Frequency
f
actual
Time delay
Safe Torque Off (STO)
11578_uk
Safe Stop 1 (SS1)
Time Delayed Safety Relay Vacon 100 Safe Torque Off (STO)
+
Subsystem
Saf ety R elay
Subsystem
STO
11579_uk

Other manuals for Vacon 100