Do you have a question about the Vacon 10 and is the answer not in the manual?
| Enclosure | IP20 |
|---|---|
| Protection Class | IP20 |
| Frequency | 50/60 Hz |
| Output Voltage | 0-Input Voltage |
| Control Method | Sensorless vector control |
| Communication Protocols | CANopen, Profibus |
| Approvals | CE, UL, cUL |
| Operating Temperature | -10°C to +50°C |
General warnings about electrical hazards and precautions.
Instructions for safe installation and operation of the frequency converter.
Requirements for proper earthing and protection against earth faults.
Checklist and procedures before starting the motor.
Explanation of the Vacon 10 type designation code and its components.
Guidelines for storing the frequency converter to maintain its condition.
Recommended maintenance, including capacitor recharge after storage.
Details of the warranty coverage and limitations for the frequency converter.
Declaration of conformity with relevant safety and EMC standards.
Methods and dimensions for physically mounting the Vacon 10 drive.
Requirements for adequate ventilation and free space for cooling the drive.
Graphs showing power losses at different switching frequencies and motor powers.
Explanation of EMC categories and procedure to change protection class.
Guidelines for power and control cabling, specifications, and rules.
Step-by-step guide for commissioning the Vacon 10 drive.
Table listing fault codes, possible causes, and correcting actions for troubleshooting.
Overview of the Vacon 10 control board and its I/O signals.
Details on I/O configuration, terminal connections, and signal descriptions.
General description of the Vacon 10 control panel, display, and keypad.
Explanation of the Vacon 10 display elements and drive status indicators.
Description of the Vacon 10 control panel keypad buttons and their functions.
Guide to navigating menus and editing parameter values on the control panel.
Lists quick setup parameters and their default values for initial configuration.
Parameters for configuring motor characteristics and settings.
Parameters for defining motor start and stop behavior.
Parameters for setting frequency references for the drive.
Parameters for configuring acceleration/deceleration ramps and braking.
Configuration of digital inputs for controlling drive functions.
Configuration of analog inputs for external signals.
Configuration of digital outputs for status signals.
Configuration of analog outputs for signal feedback.
Parameters for motor and drive protections like overcurrent, overvoltage.
Parameters for automatic fault reset functionality.
Parameters for configuring the PI controller for feedback loops.
Parameters for selecting drive application type (pump, fan, etc.).
Parameters related to system settings, communication, and software versions.
Detailed explanations of motor setting parameters.
Detailed explanations of start/stop setup parameters.
Detailed explanations of frequency reference parameters.
Detailed explanations of ramp and brake setup parameters.
Detailed explanations of digital input configuration parameters.
Detailed explanations of analog input configuration parameters.
Detailed explanations of digital output configuration parameters.
Detailed explanations of analog output configuration parameters.
Detailed explanations of protection parameters.
Detailed explanations of automatic reset parameters.
Detailed explanations of PI control parameters.
Detailed explanations of application setting parameters.
Information about the Modbus RTU bus interface, function codes, and addresses.
General technical specifications including voltage, current, power, and frequency.
Table of Vacon 10 brake resistor types and specifications.