parameter descriptions vacon • 79
24-hour support +358 (0) 201 212 575 • Email: vacon@vacon.com
9
9.5 Digital inputs (Control panel: Menu PAR -> P5)
These parameters are programmed using the FTT-method (Function To Ter-
minal), where you have a fixed input or output that you define a certain func-
tion for. You can also define more than one function to a digital input, e.g. Start
sign
al 1 and Preset Speed B1 to DI1.
The selections for these parameters are:
0 = Not used
1 = DI1
2 = DI2
3 = DI3
4 = DI4
5 = DI5
6 = DI6
5.1 I / O CTRL SIGNAL 1
5.2 I / O CTRL SIGNAL 2
5.3 REVERSE
The digital input only active when P2.4 (I/O Start stop logic) =1
The motor will run in reverse when the rising edge of P5.3 is happened.
5.4 EXTERNAL FAULT CLOSE
5.5 EXTERNAL FAULT OPEN
5.6 FAULT RESET
5.7 RUN ENABLE
5.8 PRESET SPEED B0
5.9 PRESET SPEED B1
5.10 PRESET SPEED B2
5.11 RAMP TIME 2 SELECTION
Contact open: Acceleration / Deceleration time 1 and Ramp S-shape
selected
Contact closed: Acceleration / Deceleration time 2 and Ramp S-shape2
selected
Set Acceleration / Deceleration times with parameters 4.2 and 4.3 and the al-
ternative ramp times with 4.4 and 4.5.
Set Ramp S-shape with Par. 4.1 and the alternative Ramp S-shape2 with
Par. 4.4