EasyManua.ls Logo

Vaillant ecoTEC plus VC 406/5-5 - Technical data

Vaillant ecoTEC plus VC 406/5-5
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
0020261188_00 ecoTEC plus Installation and maintenance instructions 53
H Technical data
Technical data Heating
VC 406/5-5 (E-DE) VC 406/5-5 (LL-DE)
Maximum heating flow temperature (default setting D.71)
75 75
Range for the heating flow temperature control
30 80 30 80
Maximum permissible pressure (PMS)
0.4 MPa
(4.0 bar)
0.4 MPa
(4.0 bar)
Nominal water flow (ΔT = 20 K)
1,600 l/h 1,600 l/h
Approximate value for the condensate volume (pH value between
3.5 and 4.0) at 50/30 °C
4.0 l/h 4.0 l/h
Maximum heat output (factory setting D.000)
Auto Auto
VC 476/5-5 (E-DE) VC 476/5-5 (LL-DE)
Maximum heating flow temperature (default setting D.71)
75 75
Range for the heating flow temperature control
30 80 30 80
Maximum permissible pressure (PMS)
0.4 MPa
(4.0 bar)
0.4 MPa
(4.0 bar)
Nominal water flow (ΔT = 20 K)
1,900 l/h 1,900 l/h
Approximate value for the condensate volume (pH value between
3.5 and 4.0) at 50/30 °C
4.5 l/h 4.5 l/h
Maximum heat output (factory setting D.000)
Auto Auto
VC 636/5-5 (E-DE) VC 636/5-5 (LL-DE)
Maximum heating flow temperature (default setting D.71)
75 75
Range for the heating flow temperature control
30 80 30 80
Maximum permissible pressure (PMS)
0.4 MPa
(4.0 bar)
0.4 MPa
(4.0 bar)
Nominal water flow (ΔT = 20 K)
2,500 l/h 2,500 l/h
Approximate value for the condensate volume (pH value between
3.5 and 4.0) at 50/30 °C
5.6 l/h 5.6 l/h
Maximum heat output (factory setting D.000)
Auto Auto
Technical data Power/heat input (G20)
VC 406/5-5 (E-DE) VC 476/5-5 (E-DE)
Effective output range (P) at 50/30 °C
8.7 40.7 kW 8.7 48.0 kW
Heat output range (P) at 60/40 °C
8.5 39.4 kW 8.5 46.6 kW
Effective output range (P) at 80/60 °C
7.8 37.3 kW 7.8 44.1 kW
Maximum heat input heating (Q max.)
38.0 kW 45.2 kW
Minimum heat input heating (Q min.)
8.1 kW 8.1 kW
VC 636/5-5 (E-DE)
Effective output range (P) at 50/30 °C
12.2 63.5 kW
Heat output range (P) at 60/40 °C
11.8 61.7 kW
Effective output range (P) at 80/60 °C
11.0 58.7 kW
Maximum heat input heating (Q max.)
60.0 kW
Minimum heat input heating (Q min.)
11.3 kW
Technical data Power/heat input (G25)
VC 406/5-5 (E-DE) VC 406/5-5 (LL-DE)
Effective output range (P) at 50/30 °C
8.8 40.5 kW 8.8 40.5 kW
Effective output range (P) at 80/60 °C
7.8 37.3 kW 7.8 37.3 kW
Maximum heat input heating (Q max.)
38.0 kW 38.0 kW
Minimum heat input heating (Q min.)
8.1 kW 8.1 kW