Property Specification
Temperature range 0 ... +10 °C, +30 ... +50 °C
0 ... 95%RH ±7%RH
Stability in typical HVACapplications ±2 %RH over 2 years
Product lifetime >15 years
Property Specification
Operating temperature range 0 ... +50 °C (+32 ... 122 °F)
Operating humidity range
0 ... 95 %RH
Dewpoint <30 °C (+86 °F)
Storage temperature range
Display models
-40 ... +70°C (-40 ...158°F)
-30 ... +70°C (-22 ...158°F)
Electromagnetic compliance EN61326-1,
IndustrialEnvironment
Table 7 Operating Environment
Property Specification
IP class IP30
Housing material ABS/PC UL-V0 approved
Housing color White (RAL9003)
Output connector
Screw terminal
Max wire size 2 mm
2
(AWG14)
Weight
Plain and LEDversion
114 g
Setpoint version
120 g
Display version
124 g
Table 8 Mechanics
35
6 Technical Data