Chapter 3 _____________________________________________________________Installation
VAISALA
_______________________________________________________________________ 23
CHAPTER 3
INSTALLATION
This chapter provides you with information about installing and
configuring this product.
General
SPS311 is a desktop instrument intended for use in the office or inside
a container. It can easily be fastened to an installation shelf by using
mounting straps:
- All power, signal and I/O connectors are located at the rear
- Plug-in units can be replaced through the front
SPS311 uses forced air cooling. Three fans are located below the card
frame.
NOTE
Do not block air inlet at the lower front corner of the chassis. Air
outlet is located at the upper rear corner.
Power Supply and Grounding
The SPS311 must be connected to mains power 100-240V, 1.2A Max,
50/60Hz or to a 24 VDC power system. The DC power input
connection is floating.
An external chassis ground screw is provided for system grounding.