TECHNICAL REFERENCE ________________________________________________________
34
__________________________________________________________________ M210651EN-G
RegConfig Program
RegConfig is an internal program in MRP111 and
MPU121/MPU112/MPU111 for setting communication parameters of
the unit.
The program will display the current settings and ask if they need to
be changed.
Table 15 Parameter Settings
Parameter Description Default Value
MRP111
Default Value
MPU121/MPU112/
MPU111
Hostname Computer name of the unit's
embedded PC
MRP111-<serial
number of the unit>
MPU121/MPU112/
MPU111-<serial
number of the unit>
IP-Address IP-address of the unit's
embedded PC
192.168.0.10 192.168.0.20
Subnet mask Subnet mask of the unit's
embedded PC
255.255.255.0 255.255.255.0
Default Gateway Default gateway of the unit's
embedded PC
Change this only when needed.
0.0.0.0 0.0.0.0
Vaisala Name Server IP IP-address of the Vaisala Name
Server. This is the IP-address of
the Sounding Workstation =
DigiCORA PC.
192.168.0.1 192.168.0.1
NOTE
If the network configuration of the Sounding Workstation is altered,
the network configuration of the MRP111 or
MPU121/MPU112/MPU111 unit should be altered respectively by
using the RegConfig program. Note that the network configuration of
the MRP121 does not need altering.