Chapter 3 _____________________________________________________________Installation
VAISALA
_______________________________________________________________________ 33
Speed (baud): 19200.
Data bits: 8.
Stop bits: 1.
Parity: None.
Flow Control: None.
Then select Session, click Serial and then click Open.
6. Power up the system and wait about two minutes for the system
to start.
NOTE
If you are configuring MPU121/MPU112, skip step 7 below as the
procedure does not require logging on to the system.
7. Log on to the system by typing in the following information:
Leave the Domain empty by default. This step is not performed
when configuring the MPU121/MPU112.
- User name: administrator, press ENTER.
- Domain: <empty>, press ENTER.
- Password: Administrator, press ENTER.
8. Start the RegConfig program by entering regconfig and press
ENTER.
9. If you make changes with RegConfig, you will be asked if you
want to save the changes. You need to restart the unit if you
select to save the changes.
10. If you did not make any changes, end the connection in the
following way:
- MRP111/MPU111/MWI210: Type exit and press ENTER.
o If you use HyperTerminal, select Call - Disconnect
and close the program.
o If you use PuTTYtel, close the program.
- MPU121/MPU112: Press ENTER until you get the message
"Regconfig exit".
o If you use HyperTerminal, select Call - Disconnect
and close the program.
o If you use PuTTYtel, close the program.

Table of Contents