User’s Guide ______________________________________________________________________
202 _________________________________________________________________ M211840EN-C
0505-215
Figure 47 Wind Measurement Averaging Method
I I
AA
time
1sec
time
1sec
...
...
I > A, all comm unication p rotocols other than SDI-12 (aXU,M=S). In this example I=5 sec and A=3 sec.
I < A, all comm unication p rotocols other than SDI-12 (aXU,M=S). In this example I=2 sec and A=5 sec.
I
I
II
...
...
A
A
A
A
A
time
1sec
...
Comm unication protocol SDI-12 (aXU,M=S). In this example A=3 sec. I does not have any function in this protocol.
Issuing
measurement
command
Data
ready
A
Issuing
measurement
command
Data
ready
...
Case 1
Case 2
Case 3