3 ACT 5e Digital Keypad Programming
Toenterprogrammingmode:onthedigitalkeypadpress andinputtheprogrammingcode(initially9999).
TheLEDwillflashamberwhileinprogrammingmode.Toexitprogrammingmodeeitherpress ordonot
activateanykeyfor30seconds.
3.1 Change user PIN codes
Enterprogrammingmode,thenpress:
Step Keypad Entry Operation Example
1 0 ChangePINcodes 0 ChangePINcodes
2 0-9 EnterUserNumber0-9 7 User7
3
4 0000-9999
4digitcode.
0000deletesuser.
7529 PINcode
3.2 Toggle relay
Enterprogrammingmode,thenpress:
Step Keypad Entry Operation
1 1 SetToggleMode
2 09 EnterUserNumber0–9
3 0or1
0=RelayToggle,
1=RelayTimed
3.3 Set relay active time
Enterprogrammingmode,thenpress:
Step Keypad Entry Operation
1 2 Setrelayactivetime
2 0 Relaytimer.Buzzersoundsindicatingtiming.Waitrequiredperiod.
3 Stoptiming.Buzzerstops.Timerset.
3.4 Set the backlight
Enterprogrammingmode,thenpress:
Step Keypad Entry Operation
1 40 Setpermanentbacklight.