4 ACTpro 1520e/1500e Door Controller Status Indicators
StatusindicatorsappearonthefrontoftheACTpro1520e/1500eDoorController.
Themeaningofeachindicatorisdescribedbelow.
(A) Power / System Running
ThisindicatesthattheACTpro1520e/1500ehaspower.
(B) Communications
Constantilluminationindicatesthatallenableddoorstationsareonline.
Flashingindicatesthatoneormoredoorstationsareoffline.
(C) Fault
Illuminatestoindicateafaultonthesystem.
Possiblecausesare:
l Tamperopen:ACTproControllerhousingisnotclosed.
l BreakGlass:ACTproControllersprovideamethodtomonitoranEmergencybreakglassswitchviathe
B/GLinput.ThefaultLEDwillilluminateiftheEmergencybreakglassswitchisactivated.
l MainsFault:ACTpro1500eControllerwillacceptamainspresentsignalfromaPSU(pre-wiredon
ACTpro1520e).ThisiswiredintoMAINSPRESENTinputonthePCB.WhenthePSUhasnomains
supplythefaultisactive.
l DoorStationoffline:WhenoneormoreenableddoorstationsarenotcommunicatingwiththeACTpro
ControllertheFaultLEDilluminatesandtheappropriatenetworkgreenLEDonthePCBwillflash.
l LowSupplyVoltage:Whenvoltagetothe+12Vterminalislessthan+9V.
l FuseBlown:The+12VoutputontheREADERterminalsiscurrentlimitedtoprovideshortcircuit
protection.TheFaultLEDwillilluminateiftoomuchcurrentisdrawnfromthisconnection.