SECTION TWO - Setup & Testing CC-STAT
©Vantage, 41184 / IS-1308191-A page 15 of 23
Installer System Settings Table (continued)
System setting Description
Factory default setting (bold) and
setting range
41.
LOCKOUT TYPE Screen lockout level. (Override lockout by
holding [MENU] for 7 seconds).
OFF
PARTIAL
FULL
42.
MODE LOCKOUT System mode lockout setting.
DISABLE
ENABLE
43.
FAN LOCKOUT Fan Mode lockout setting.
OFF
TIMED
FULL
44.
SETPOINT LOCKOUT TYPE
Setpoint lockout setting.
OFF
TIME-LIMITED
RANGE-LIMITED
TIME AND RANGE
FULL
45.
MAX SETPOINT CHANGE
IN LOCKOUT
Select setpoint limits (only available when
lockout is set to partial lockout).
+/-5 DEGREES (from current setpoint)
±1° to 20° OFF indicates no setpoint
changes
or
+/-5% RH (from current setpoint)
±1% to 20% OFF indicates no setpoint
changes
46.
TEMPORARY CHANGE
PERIOD
Time-limited lockout temporary change period.
60 MINUTES
Select 0 to 255 minutes in 5 minute step;
0 indicates no temporary change period.
47.
NETWORK OVERRIDE Network override feature setting.
ENABLE
DISABLE
48.
DISPLAY REMOTE SENSORS
Enable or disable display of support module
monitor (remote) sensor readings.
ENABLE
DISABLE
49.
AIR FILTER ALARM PERIOD
The period for displaying the “Change Air
Filter” message.
OFF
1, 3, 6, 12 MONTHS or “OFF” to disable
50.
WATER PANEL ALARM
PERIOD
Set number of months until the first reminder
is
required. The following reminders will occur
every 12 months for a flow through humidifier,
and 3/9 months for a drainless humidifier.
OFF
1 to 12 MONTHS or “OFF” to disable
51.
HUMIDIFIER TYPE Select humidifier type. Flow through type
gives
a 12 month reminder, and drainless gives a 3/9
month reminder.
FLOW THROUGH (1 reminder per season)
DRAINLESS (2 reminders per season)
52.
DEHUMIDIFIER ALARM
PERIOD
The period for displaying the “Service
Dehumidifier” message.
OFF
1 to 12 MONTHS or “OFF” to disable
53.
HVAC ALARM PERIOD The period for displaying the “Service HVAC”
message.
OFF
1 to 12 MONTHS or “OFF” to disable