SECTION SIX - Error Codes CC-STAT
©Vantage, 41184 / IS-1308191-A page 22 of 23
SECTION SIX – ERROR CODES
If the thermostat enters an error mode, all outputs are turned off. The thermostat attempts to
recover every 10 minutes. If the error does not clear, use the reset* button. This will return all
settings back to factory default.
Error Code Message Error Description
01
“SENSOR ERROR”
Open temperature sensor circuit
02 Shorted temperature sensor circuit
03
“RH SENSOR
ERROR”
Invalid response from the RH sensor
04 “EEPROM ERROR” Error in permanent memory
05 “SENSOR ERROR”
All controlling support modules are unresponsive and
the built-in sensor is not used as a backup option
*CAUTION: Thermostat power must be cycled after a reset for the CC-WLINT or CC-RLINT