Type:
(RVU) residential ventilation unit
Vasco DX4 Vasco DX4
Vasco DX4
+ 1 sensor
Vasco DX4
+ 2 sensors
Type of climate Cold Average Warm Cold Average Warm Cold Average Warm Cold Average Warm
Specific energy consumption (SEC) kWh/(m²a) -76,51 -37,97 -13,27 -77,54 -38,86 -14,07 -79,49 -40,51 -15,56 -82,95 -43,38 -18,08 kWh/(m²a)
SEC class
A+ A E A+ A E A+ A E A+ A+ E
Declared typology ventilation unit
Bidirectional ventilation unit (BVU) Bidirectional ventilation unit (BVU) Bidirectional ventilation unit (BVU) Bidirectional ventilation unit (BVU)
Type of drive installed Variable speed Variable speed Variable speed Variable speed
Type of heat recovery system Recuperative heat exchanger Recuperative heat exchanger Recuperative heat exchanger Recuperative heat exchanger
Thermal efficiency of heat recovery % 92,70% 92,70% 92,70% 92,70% %
Maximum flow rate m³/h 400 400 400 400 m³/h
Electric power input W 167 167 167 167 W
Sound power level L
WA
dB(A) 51 51 51 51 dB(A)
Reference flow rate m³/s 0,0778 0,0778
0,0778 0,0778 m³/s
Reference pressure difference Pa 50 50 50 50 Pa
Specific power input (SPI) W/m³/h 0,250 0,250 0,250 0,250 W/m³/h
Control typology Manual Control (no DCV) Clockcontrol (no DCV)
Central demand control Local demand control
Control factor 1 0,95 0,85 0,65
Declared maximum internal and
external leakage rates
Internal A1(1,1%) A1 (1,1%)
A1 (1,1%) A1 (1,01%) Internal
External A1(1,6%) A1(1,6%) A1(1,6%) A1(1,6%) External
Mixing rate of non-ducted
bidirectional ventilation units
% -
- %
Position and description of visual
filter warning for RVUs
The LED on the included RF switch that lights up orange twice
(after operation) when the filters should be replaced. Periodically replacing
the air filters is important for the optimal funtioning of the ventilation
unit. Not replacing the air filter has an impact on the yield and the energy
effeciency of the device.
The LED on the included RF switch that lights up orange twice
(after operation) when the filters should be replaced. Periodically replacing
the air filters is important for the optimal funtioning of the ventilation unit. Not
replacing the air filter has an impact on the yield and the energy effeciency of
the device.
Internet address for
pre-/dis-assembly instructions
www.vasco.eu www.vasco.eu
The airflow sensitivity to pressure variations
(for non-ducted units only)
% - - %
The indoor/outdoor air tightness
(for non-ducted units only)
Indoor: m³/h -
- Indoor: m³/h
Outdoor: m³/h - - Outdoor: m³/h
Annual electricity consumption
per 100m² surface (AEC)
kWh
electricity/a
895 358 313 864 327 282
808 271 226 714 177 132
kWh
electricity/a
Annual saved primary heating energy
per 100m² groundsurface (AHS)
kWh primary
energy/a
9132 4668 2111 9154 4680 2116
9200 4703 2127 9291 4749 2148
kWh primary
energy/a
VENTILATION SYSTEM DX4
36 PRODUCT DATA SHEET DX4
DECLARATION OF
PERFORMANCE