Type:
(RVU) residential ventilation unit
Vasco DX6 Vasco DX6
Vasco DX6
+ 1 sensor
Vasco DX6
+ 2 sensors
Type of climate Cold Average Warm Cold Average Warm Cold Average Warm Cold Average Warm
Specific energy consumption (SEC) kWh/(m²a) -74,00 -34,89 -9,85 -75,33 -36,10 -11,00 -77,83 -38,36 -13,12 -82,16 -42,21 -16,70 kWh/(m²a)
SEC class
A+ A F A+ A E A+ A E A+ A+ E
Declared typology ventilation unit
Bidirectional ventilation unit (BVU) Bidirectional ventilation unit (BVU) Bidirectional ventilation unit (BVU) Bidirectional ventilation unit (BVU)
Type of drive installed Variable speed Variable speed Variable speed Variable speed
Type of heat recovery system Recuperative heat exchanger Recuperative heat exchanger Recuperative heat exchanger Recuperative heat exchanger
Thermal efficiency of heat recovery % 92,2% 92,2% 92,2% 92,2% %
Maximum flow rate m³/h 570 570 570 570 m³/h
Electric power input W 340 340 340 340 W
Sound power level L
WA
dB(A) 59 59 59 59 dB(A)
Reference flow rate m³/s 0,1108 0,1108
0,1108 0,1108 m³/s
Reference pressure difference Pa 50 50 50 50 Pa
Specific power input (SPI) W/m³/h 0,357 0,357 0,357 0,357 W/m³/h
Control typology Manual Control (no DCV) Clockcontrol (no DCV)
Central demand control Local demand control
Control factor 1 0,95 0,85 0,65
Declared maximum internal and
external leakage rates
Internal A1 (0,8%) A1 (0,8%)
A1 (0,8%) A1 (0,8%) Internal
External A1 (1,1%) A1 (1,1%) A1 (1,1%) A1 (1,1%) External
Mixing rate of non-ducted
bidirectional ventilation units
% -
- %
Position and description of visual
filter warning for RVUs
The LED on the included RF switch that lights up orange twice
(after operation) when the filters should be replaced. Periodically replacing
the air filters is important for the optimal funtioning of the ventilation
unit. Not replacing the air filter has an impact on the yield and the energy
effeciency of the device.
The LED on the included RF switch that lights up orange twice
(after operation) when the filters should be replaced. Periodically replacing
the air filters is important for the optimal funtioning of the ventilation
unit. Not replacing the air filter has an impact on the yield and the energy
effeciency of the device.
Internet address for
pre-/dis-assembly instructions
www.vasco.eu www.vasco.eu
The airflow sensitivity to pressure variations
(for non-ducted units only)
% - - %
The indoor/outdoor air tightness
(for non-ducted units only)
Indoor: m³/h -
- Indoor: m³/h
Outdoor: m³/h - - Outdoor: m³/h
Annual electricity consumption
per 100m² surface (AEC)
kWh
electricity/a
1029 492 447 986 449 404
905 368 323 771 234 189
kWh
electricity/a
Annual saved primary heating energy
per 100m² groundsurface (AHS)
kWh primary
energy/a
9100 4652 2104 9125 4664 2109
9173 4689 2120 9271 4739 2143
kWh primary
energy/a
Product sheet following Delegated Regulation (EU) No 1254/2014 & 1253/2014
PRODUCT DATA SHEET DX6 41